List of calculation methods and data needed
Method | Description | Required input data | Additional parameters | Remark |
1 | Dewpoint | dewpoint temperature | - | default calculation method |
2 | Psychrometric Data | dry and wet bulb temperature | altitude, psychrometric constant of instrument (default 0.00080) | |
3 | Relative max and min humidity | max and min relative humidity, min and max temperature | - | - |
4 | Relative max humidity | max relative humidity, min temperature | ||
5 | Relative mean humidity | mean relative humidity, min and max temperature |
For documentation of the formulas please check the orginal reference (FAO 56)
Content Type | Name | Description | Data Type | Unit | Min Value | Max Value | Default Value |
---|---|---|---|---|---|---|---|
constant | cAltitude | elevation above sea level | DOUBLE | m | - | - | 0.0 |
constant | cCalculationMethod | calculation method | INT | - | - | 1 | |
constant | cPsychrometricConstantInstrument | psychrometric constant of instrument | DOUBLE | 1 | - | - | 8.0E-4 |
input | iRelHumidityMax | maximum relative humidity | DOUBLE | % | - | - | 0.0 |
input | iRelHumidityMean | mean relative humidity | DOUBLE | % | - | - | 0.0 |
input | iRelHumidityMin | minimum relative humidity | DOUBLE | % | - | - | 0.0 |
input | iTDewpoint | dew point temperature | DOUBLE | °C | - | - | 0.0 |
input | iTDryBulb | dry bulb temperature | DOUBLE | °C | - | - | 0.0 |
input | iTMax | maximum daily temperature | DOUBLE | °C | - | - | 0.0 |
input | iTMin | minimum daily temperature | DOUBLE | °C | - | - | 0.0 |
input | iTWetBulb | wet bulb temperature | DOUBLE | °C | - | - | 0.0 |
out | ActualVapourPressure | actual vapour pressure | DOUBLE | kPa | - | - | 0.0 |